Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 469
Filtrar
1.
J Vet Intern Med ; 38(1): 285-299, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38084870

RESUMO

BACKGROUND: High-salt diets promote urine dilution and decrease urolithiasis risk. OBJECTIVE: Prospectively evaluate the safety of chronic high dietary salt intake (randomized controlled trial). ANIMALS: Twenty research colony neutered, healthy aged cats (11.5 years [10.0-11.6], median [interquartile range]). METHODS: Healthy cats were randomized to control or high-salt dry diets (sodium: 1.02 ± 0.16 [mean, SD] and 3.26 ± 0.30 g/Mcal metabolizable energy [ME], respectively; chloride: 2.26 ± 0.33 and 5.71 ± 0.28 g/Mcal ME, respectively), fed for up to 60 months. Assessments included CBC, plasma biochemistry, urinalysis, glomerular filtration rate (GFR), blood pressure, renal and cardiac (conventional Doppler and 2-dimensional color tissue Doppler) imaging, annually. Cats that died or were euthanized underwent necropsy. Diet effects over time were evaluated with linear mixed models. RESULTS: Follow-up duration (median [Interquartile range]) was similar between the control (38.7 months [28.6-48.2]) and high-salt group (51.4 months [45.7-59.0]). Diet had no significant effect on changes in GFR, blood pressure, plasma creatinine concentration, end-diastolic left ventricular (LV) wall thicknesses, LV internal diameters, LV systolic function, left atrial size, or systolic and diastolic Doppler variables. One control cat developed hypertension. One high-salt group cat developed persistent azotemia. Serial plasma biochemistry and urine specific gravity suggested early chronic kidney disease in 4 nonazotemic cats (2 per group), consistent with necropsy findings. CONCLUSIONS AND CLINICAL IMPORTANCE: In healthy aged cats, a commercial veterinary diet containing 3.26 ± 0.30 g/Mcal ME sodium was safe with regard to renal and cardiac function for up to 5 years.


Assuntos
Arachis , Cloreto de Sódio na Dieta , Gatos , Animais , Cloreto de Sódio na Dieta/efeitos adversos , Estudos Prospectivos , Rim , Sódio
2.
Clin Microbiol Infect ; 27(6): 878-885, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32896653

RESUMO

OBJECTIVES: Protection induced by acellular vaccines can be short, requiring novel immunization strategies. Objectives of this study were to evaluate safety and capacity of a recombinant pertussis toxin (PTgen) -coated Viaskin® epicutaneous patch to recall memory responses in healthy adults. METHODS: This double-blind, placebo-controlled randomized trial (Phase I) assessed the safety and immunogenicity of PTgen administered on days 0 and 14 to healthy adults using Viaskin® patches applied directly or after epidermal laser-based skin preparation. Patch administration was followed by Boostrix®dTpa on day 42. Antibodies were assessed at days 0, 14, 28, 42 and 70. RESULTS: Among 102 volunteers enrolled, 80 received Viaskin-PT (Viaskin-PT 25 µg (n = 25), Viaskin-PT 50 µg (n = 25), laser + Viaskin-PT 25 µg (n = 5), laser + Viaskin-PT 50 µg (n = 25)), Viaskin-placebo (n = 10) or laser + Viaskin-placebo (n = 2). Incidence of adverse events was similar across groups (any local event: 21/25 (84.0%), 24/25 (96.0%), 4/5 (80.0%), 24/25 (96.0%), 8/10 (80.0%), 10/12 (83.0%), respectively). Direct application induced no detectable response. On day 42, PT-IgG geometric mean concentrations were significantly higher following laser + Viaskin-PT 25 µg and 50 µg (139.87 (95% CI 87.30-224.10) and 121.76 (95% CI 95.04-156.00), respectively), than laser + Viaskin-placebo (59.49, 95% CI 39.37-89.90). Seroresponse rates were higher following laser + Viaskin-PT 25 µg (4/5 (80.0%), 95% CI 28.4-99.5) and 50 µg (22/25 (88.0%), 95% CI 68.8-97.5) than laser + Viaskin-placebo (0/12 (0.0%), 95% CI 0.0-26.5). CONCLUSIONS: Viaskin-PT applied after laser-based epidermal skin preparation showed encouraging safety and immunogenicity results: anti-PT booster responses were not inferior to those elicited by Boostrix®dTpa. This study is registered at ClinicalTrials.gov (NCT03035370) and was funded by DBV Technologies.


Assuntos
Toxina Pertussis/imunologia , Administração Cutânea , Adolescente , Adulto , Anticorpos Antibacterianos/sangue , Anticorpos Antibacterianos/imunologia , Método Duplo-Cego , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Masculino , Toxina Pertussis/administração & dosagem , Adulto Jovem
3.
J Vet Intern Med ; 35(1): 303-311, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33274800

RESUMO

BACKGROUND: Glomerular filtration rate (GFR) is the gold standard in assessing renal function but is impractical. Serum creatinine (sCr) has limited sensitivity in identifying early chronic kidney disease (CKD), whereas symmetric dimethylarginine (SDMA) has been commercialized as more accurate biomarker. Studies comparing SDMA and sCr with GFR in cats are limited. OBJECTIVES: To further investigate the diagnostic performance of SDMA in nonazotemic and azotemic cats. ANIMALS: Forty-nine client-owned cats: 17 cats with CKD, 15 cats with diabetes mellitus (DM), and 17 healthy cats. METHODS: Retrospective study using spare blood samples from cats with documented sCr and GFR results for SDMA analysis. Diagnostic performances of SDMA and sCr were evaluated using correlation coefficients, sensitivities, specificities, and receiver operator characteristic curves. RESULTS: Compared to healthy cats and cats with DM, CKD cats had significantly higher SDMAplasma (26.7 ± 9.9 µg/dL) and sCr (249.7 ± 71.6 µmol/L [2.8 ± 0.8 mg/dL]; both P < .001) values. SDMAplasma (τB = -0.57; P < .001) and sCr (τB = -0.56; P < .001) were significantly correlated with GFR. SDMAplasma (τB = 0.52; P < .001) had a significant relationship with sCr. SDMAplasma and sCr had similar sensitivity (76%-94% and 71%-88%, respectively) in detecting reduced renal function. Creatinine had higher specificity (94%-96%) than SDMAplasma (75%-76%) (P < .05). CONCLUSION AND CLINICAL IMPORTANCE: In this study of azotemic and nonazotemic cats, SDMA was a reliable marker to identify decreased GFR. However, superiority of SDMA over sCr could not be confirmed.


Assuntos
Arginina , Insuficiência Renal Crônica , Animais , Arginina/análogos & derivados , Biomarcadores , Creatinina , Taxa de Filtração Glomerular/veterinária , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/veterinária , Estudos Retrospectivos
4.
Vet Surg ; 49(6): 1075-1087, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32677115

RESUMO

OBJECTIVE: To describe clinical applications of computer-assisted orthopedic surgery (CAOS) in horses with a navigation system coupled with a cone beam computed tomography unit. STUDY DESIGN: Retrospective clinical case series. ANIMALS: Thirteen adult horses surgically treated with CAOS. METHODS: Medical records were searched for horses that underwent CAOS between 2016 and 2019. Data retrieved included signalment, diagnosis, lameness grade prior to surgery, surgical technique and complications, anesthesia and surgery time, and information pertaining to the perioperative case management and outcome. RESULTS: In 10 cases, surgical implants were placed in the proximal phalanx, third metatarsal bone, ulna, or medial femoral condyle. In one case, navigated transarticular drilling was performed to promote ankylosis of the distal tarsal joints. In another case, an articular fragment of the middle phalanx was removed with the help of CAOS guidance. In the final case, a focal osteolytic lesion of the calcaneal tuber was curetted with the aid of CAOS. In seven cases, a purpose-built frame was used for the surgical procedure. All surgeries were performed successfully and according to the preoperative plan. CONCLUSION: Computer-assisted orthopedic surgery can be an integral part of the clinical case management in equine surgery. To optimize workflow and time-efficiency, the authors recommend designating one team for operative planning and another for the execution of the surgical plan. Specialized equipment, such as the purpose-built frame, will further improve CAOS applications in equine surgery. CLINICAL SIGNIFICANCE: After they have become familiar with the operational principles, equine surgeons can readily apply CAOS for a broad spectrum of indications.


Assuntos
Tomografia Computadorizada de Feixe Cônico/veterinária , Cavalos/cirurgia , Procedimentos Ortopédicos/veterinária , Cirurgia Assistida por Computador/veterinária , Animais , Feminino , Membro Anterior/cirurgia , Membro Posterior/cirurgia , Masculino , Procedimentos Ortopédicos/métodos , Estudos Retrospectivos , Cirurgia Assistida por Computador/métodos , Articulações Tarsianas/cirurgia
5.
J Vet Intern Med ; 33(2): 516-522, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30632628

RESUMO

BACKGROUND: Measurement of serum creatinine (sCr) and urea nitrogen fail to detect decreased renal function in many hyperthyroid cats because of low muscle mass and glomerular hyperfiltration of affected cats. Serum symmetric dimethylarginine (sSDMA) is an earlier and more sensitive renal biomarker than sCr. OBJECTIVE: Evaluate sSDMA as a biomarker of renal function in hyperthyroid cats before (T0) and 1 month after (T1) radioiodine (131 I) treatment. ANIMALS: Forty-seven client-owned hyperthyroid nonazotemic cats were evaluated at T0 and T1. METHODS: A prospective study in which sCr and sSDMA concentrations were determined in 47 hyperthyroid cats at T0 and at T1. Glomerular filtration rate (GFR) was estimated at T0 and T1 in 10 of these 47 cats using plasma exogenous creatinine clearance test. RESULTS: Serum SDMA was elevated (>14 µg/dL) in 6 of 47 cats at T0 and normalized after treatment in 4 of those cats. All cats remained nonazotemic after treatment. In 10 cats in which GFR was measured, correlation between GFR and sSDMA was low and not significant (τb = -0.35, P = .17 at T0 and τb = -.22, P = .41 at T1), whereas correlation between GFR and sCr was moderate and significant (τb = -0.52, P < .05 at T0 and τb = -.53, P = <.05 at T1). CONCLUSIONS AND CLINICAL IMPORTANCE: Careful interpretation of mildly increased sSDMA with normal sCr in hyperthyroid cats is warranted as sSDMA values might normalize after resolution of hyperthyroidism in some cats. In this population of hyperthyroid cats, sSDMA was poorly correlated with GFR.


Assuntos
Arginina/análogos & derivados , Biomarcadores/sangue , Doenças do Gato/sangue , Radioisótopos do Iodo/uso terapêutico , Animais , Arginina/sangue , Nitrogênio da Ureia Sanguínea , Doenças do Gato/radioterapia , Gatos , Creatinina/sangue , Feminino , Taxa de Filtração Glomerular/veterinária , Hipertireoidismo/sangue , Hipertireoidismo/radioterapia , Hipertireoidismo/veterinária , Testes de Função Renal/veterinária , Masculino , Estudos Prospectivos
6.
Rev Sci Instrum ; 90(12): 124902, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31893770

RESUMO

This paper presents the development of a new system designed to measure the local temperature field in adiabatic shear bands. Transient temperature fields are simultaneously recorded by using an array of 32 InSb infrared (IR) detectors and a streak camera working in visible-near infrared (VIS-NIR). Observations in IR offer a low temperature detection limit (550 K), but they are highly sensitive to uncertainties in emissivity. Observations in VIS-NIR allow for measurements only at high temperatures (>1000 K), but they are less affected by uncertainties in emissivity and present a higher temperature sensitivity. By performing simultaneous measurements, it is possible to obtain data in a large temperature range with an improved accuracy at high temperature. The different sources of error caused by uncertainties in emissivity, spatial resolution, and temporal resolution have been analyzed, and an estimation of the total measurement uncertainties of the system is given.

7.
J Vet Sci ; 19(5): 683-692, 2018 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-30041288

RESUMO

Our aim was (1) to determine the within-day and between-day variability of several indices of systolic and diastolic right ventricular (RV) function by using conventional echocardiography and speckle-tracking echocardiography (STE) (Study 1), (2) to quantify these variables in a large healthy canine population (n = 104) with Doppler-derived estimated systolic pulmonary arterial pressure (SPAP) and left ventricular (LV) function, and (3) to establish the corresponding reference intervals (Study 2). For both studies, RV variables included tricuspid annular plane systolic excursion (TAPSE), right fractional area change (RFAC), STE longitudinal systolic strain (StS) of the RV free wall (RVFW) and of the entire RV (i.e., global RV StS), STE longitudinal systolic RVFW strain rate (SRS), and the diastolic early:late strain rate ratio. All but one within- and between-day coefficients of variation (13/14) were < 15%, the lowest being observed for TAPSE (3.6-9.8%), global RV StS (3.8-9.9%), and RVFW StS (3.7-7.3%). SPAP was weakly and negatively correlated with the TAPSE:body weight ratio (rs = -0.26, p = 0.01) and RVFW SRS (rs = -0.23, p < 0.05). Reference intervals (lower and upper limits with 90% confidence intervals) were provided for all variables. STE provides a non-invasive evaluation of RV function that may be used for clinical investigations in canine cardiology.


Assuntos
Ecocardiografia/veterinária , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Direita , Animais , Cães , Ecocardiografia Doppler/veterinária , Feminino , Masculino , Estudos Prospectivos , Valores de Referência
8.
Rev Mal Respir ; 35(10): 1050-1062, 2018 Dec.
Artigo em Francês | MEDLINE | ID: mdl-29945812

RESUMO

The right ventricle (RV) plays a key role in the maintenance of an adequate cardiac output whatever the demand, and thus contributes to the optimization of the ventilation/perfusion ratio. The RV has a thin wall and it buffers the physiological increases in systemic venous return without causing a deleterious rise in right atrial pressure (RAP). The RV is coupled to the pulmonary circulation which is a low pressure, low resistance, high compliance system. In the healthy subject at rest, the contribution of the RV to right heart systolic function is surpassed by the contribution of both left ventricular contraction and the respiratory pump. RV systolic function plays a contributory role during exercise and in patients with pulmonary hypertension. The RV compensates better for volume overload than for pressure overload and is more capable of sustaining chronic increases in load than acute ones. An impaired RV-pulmonary artery coupling leads to a major mismatch between RV function and arterial load ("afterload mismatch") and is associated progressively with a low cardiac output and a high RAP. Right ventricular dysfunction is involved in the pathophysiology of both cardiovascular and pulmonary diseases, and may partly explain the deleterious haemodynamic consequences of mechanical ventilation.


Assuntos
Ventrículos do Coração/fisiopatologia , Hemodinâmica/fisiologia , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Direita/fisiologia , Adaptação Fisiológica/fisiologia , Humanos , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/fisiopatologia , Artéria Pulmonar/fisiopatologia , Circulação Pulmonar/fisiologia , Volume Sistólico/fisiologia
9.
Hum Factors ; 60(1): 31-56, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28965433

RESUMO

OBJECTIVE: To examine the relationship between experienced mental workload and physiological response by noninvasive monitoring of physiological parameters. BACKGROUND: Previous studies have examined how individual physiological measures respond to changes in mental demand and subjective reports of workload. This study explores the response of multiple physiological parameters and quantifies their added value when estimating the level of demand. METHOD: The study presented was conducted in laboratory conditions and required participants to perform a visual-motor task that imposed varying levels of demand. The data collected consisted of physiological measurements (heart interbeat intervals, breathing rate, pupil diameter, facial thermography), subjective ratings of workload (Instantaneous Self-Assessment Workload Scale [ISA] and NASA-Task Load Index), and the performance. RESULTS: Facial thermography and pupil diameter were demonstrated to be good candidates for noninvasive workload measurements: For seven out of 10 participants, pupil diameter showed a strong correlation ( R values between .61 and .79 at a significance value of .01) with mean ISA normalized values. Facial thermography measures added on average 47.7% to the amount of variability in task performance explained by a regression model. As with the ISA ratings, the relationship between the physiological measures and performance showed strong interparticipant differences, with some individuals demonstrating a much stronger relationship between workload and performance measures than others. CONCLUSION: The results presented in this paper demonstrate that physiological and pupil diameter can be used for noninvasive real-time measurement of workload. APPLICATION: The methods presented in this article, with current technological capabilities, are better suited for workplaces where the person is seated, offering the possibility of being applied to pilots and air traffic controllers.


Assuntos
Função Executiva/fisiologia , Face/fisiologia , Frequência Cardíaca/fisiologia , Desempenho Psicomotor/fisiologia , Pupila/fisiologia , Respiração , Adulto , Eletrocardiografia , Medições dos Movimentos Oculares , Feminino , Humanos , Masculino , Termografia , Adulto Jovem
10.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-758844

RESUMO

Our aim was (1) to determine the within-day and between-day variability of several indices of systolic and diastolic right ventricular (RV) function by using conventional echocardiography and speckle-tracking echocardiography (STE) (Study 1), (2) to quantify these variables in a large healthy canine population (n = 104) with Doppler-derived estimated systolic pulmonary arterial pressure (SPAP) and left ventricular (LV) function, and (3) to establish the corresponding reference intervals (Study 2). For both studies, RV variables included tricuspid annular plane systolic excursion (TAPSE), right fractional area change (RFAC), STE longitudinal systolic strain (StS) of the RV free wall (RVFW) and of the entire RV (i.e., global RV StS), STE longitudinal systolic RVFW strain rate (SRS), and the diastolic early:late strain rate ratio. All but one within- and between-day coefficients of variation (13/14) were < 15%, the lowest being observed for TAPSE (3.6–9.8%), global RV StS (3.8–9.9%), and RVFW StS (3.7–7.3%). SPAP was weakly and negatively correlated with the TAPSE:body weight ratio (r(s) = −0.26, p = 0.01) and RVFW SRS (r(s) = −0.23, p < 0.05). Reference intervals (lower and upper limits with 90% confidence intervals) were provided for all variables. STE provides a non-invasive evaluation of RV function that may be used for clinical investigations in canine cardiology.


Assuntos
Animais , Cães , Pressão Arterial , Cardiologia , Diástole , Ecocardiografia , Coração , Miocárdio , Estudos Prospectivos , Sístole , Função Ventricular Direita
11.
Org Process Res Dev ; 21(7): 1042-1050, 2017 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-28781513

RESUMO

We report the construction and use of a vortex reactor which uses a rapidly rotating cylinder to generate Taylor vortices for continuous flow thermal and photochemical reactions. The reactor is designed to operate under conditions required for vortex generation. The flow pattern of the vortices has been represented using computational fluid dynamics, and the presence of the vortices can be easily visualized by observing streams of bubbles within the reactor. This approach presents certain advantages for reactions with added gases. For reactions with oxygen, the reactor offers an alternative to traditional setups as it efficiently draws in air from the lab without the need specifically to pressurize with oxygen. The rapid mixing generated by the vortices enables rapid mass transfer between the gas and the liquid phases allowing for a high efficiency dissolution of gases. The reactor has been applied to several photochemical reactions involving singlet oxygen (1O2) including the photo-oxidations of α-terpinene and furfuryl alcohol and the photodeborylation of phenyl boronic acid. The rotation speed of the cylinder proved to be key for reaction efficiency, and in the operation we found that the uptake of air was highest at 4000 rpm. The reactor has also been successfully applied to the synthesis of artemisinin, a potent antimalarial compound; and this three-step synthesis involving a Schenk-ene reaction with 1O2, Hock cleavage with H+, and an oxidative cyclization cascade with triplet oxygen (3O2), from dihydroartemisinic acid was carried out as a single process in the vortex reactor.

12.
Vet Clin Pathol ; 45(2): 320-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27228235

RESUMO

BACKGROUND: Serum cystatin C (sCysC) is used as biomarker for glomerular filtration rate (GFR). The effects of diabetes mellitus (DM) on renal function in dogs are unclear. Some renal variables have been evaluated in dogs with hyperadrenocorticism (HAC), but not sCysC. OBJECTIVES: The purpose of this study was the validation of a particle-enhanced nephelometric immunoassay (PENIA) for measuring canine sCysC, and to assess renal function in dogs with DM or HAC. METHODS: A PENIA was analytically validated for canine sCysC by determining imprecision and linearity. In a longitudinal 6-month study, renal function of 14 DM dogs was assessed, using serum creatinine, GFR, urinary protein-to-creatinine (UPC) ratio, urinary markers, systolic blood pressure (SBP), and sCysC, and compared to 17 healthy dogs at baseline. Furthermore, sCysC was measured at initial presentation and during a 12-month follow-up in 22 HAC dogs. RESULTS: The sCysC intra- and inter-assay variation coefficients were < 8% and highly linear (r = .997). About 33% and 67% of DM dogs had persistent proteinuria and systemic hypertension, respectively, but there were no significant differences in GFR, UPC, and urinary markers over time, and compared with healthy dogs at initial presentation. Serum CysC decreased significantly (P < .05) over time within the DM group. It did not change significantly over time within the HAC group. CONCLUSIONS: A PENIA measured sCysC linearly and precisely. There were no clinically relevant renal alterations over time in dogs with DM, although persistent proteinuria was observed. In dogs with HAC, sCysC measurement was not useful, although significant GFR changes occurred over time.


Assuntos
Hiperfunção Adrenocortical/veterinária , Cistatina C/sangue , Diabetes Mellitus/veterinária , Rim/metabolismo , Hiperfunção Adrenocortical/sangue , Animais , Diabetes Mellitus/sangue , Cães , Seguimentos
13.
J Feline Med Surg ; 18(3): 219-39, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26936494

RESUMO

PRACTICAL RELEVANCE: Chronic kidney disease (CKD) is one of the most commonly diagnosed diseases in older cats. In most cats, CKD is also a progressive disease and can be accompanied by a wide range of clinical and clinicopathological changes. These ISFM Consensus Guidelines have been developed by an independent panel of clinicians and academics to provide practical advice on the diagnosis and management of this complex disease. CLINICAL CHALLENGES: Although CKD is a common clinical problem in cats, the manifestations of disease vary between individuals. Thus there is a need for careful and repeat evaluation of cats with CKD and adjustment of therapy according to individual needs. In addition to addressing problems arising from CKD and improving quality of life (QoL) for the patient, therapy may also target slowing the underlying progression of disease and hence prolonging life. While maintaining QoL is of paramount importance in our patients, this can be challenging when multiple therapies are indicated. In some cases it is necessary to prioritise therapy, given an understanding of what is likely to most benefit the individual patient. EVIDENCE BASE: In preparing these Guidelines, the Panel has carefully reviewed the existing published literature, and has also graded the quality of evidence for different interventions to help to provide practical recommendations on the therapeutic options for feline CKD. This is a field of veterinary medicine that has benefited from some excellent published clinical research and further research findings will undoubtedly modify the recommendations contained in these Guidelines in the future.


Assuntos
Doenças do Gato/diagnóstico , Doenças do Gato/terapia , Guias de Prática Clínica como Assunto , Insuficiência Renal Crônica/veterinária , Animais , Gatos , Consenso , Gerenciamento Clínico , Progressão da Doença , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/terapia , Sociedades Médicas
14.
Vet Surg ; 44(7): 809-15, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26197984

RESUMO

OBJECTIVE: To characterize the configuration of incomplete proximal fractures of the proximal phalanx (P1) in horses not used for racing and compare radiographic with computed tomography (CT) findings. STUDY DESIGN: Historical cohort. ANIMALS: Twenty-four horses with incomplete fractures of P1. METHODS: Medical records of horses not used for racing diagnosed with an incomplete proximal fracture of P1 based on clinical and radiographic examination and confirmed by CT between 2008 and 2013 were retrieved. Radiographs and CT studies of these horses were analyzed using a subjective grading system and by measuring variables that characterized fracture configuration. RESULTS: Twenty-four horses were included (20 Warmbloods) with a mean age of 9.5 years and mean body weight of 574 kg. Fourteen forelimbs and 10 hind limbs were affected. Mean duration of lameness was 8.7 weeks. Computed tomography was superior to radiography in both identifying the fracture and determining fracture size and location. On CT, 92% of fractures were located in the mid-sagittal plane. Mean proximodistal length of the fracture was 13 mm. Fractures were frequently not bicortical. Fractures in forelimbs were located significantly more dorsally than fractures in hind limbs. A distinct fracture pattern with 2 subchondral lines running parallel in close proximity to each other was identified in 54% of cases. CONCLUSION: Incomplete proximal fractures of P1 have significant variation in their configurations, especially their dorsopalmar/-plantar location. Computed tomography examination allowed clear identification of the fracture configurations and was superior to radiography.


Assuntos
Fraturas Ósseas/veterinária , Cavalos/lesões , Radiografia/veterinária , Animais , Feminino , Membro Anterior/diagnóstico por imagem , Membro Anterior/lesões , Fraturas Ósseas/diagnóstico por imagem , Membro Posterior/diagnóstico por imagem , Membro Posterior/lesões , Masculino , Radiografia/métodos , Falanges dos Dedos do Pé/diagnóstico por imagem , Falanges dos Dedos do Pé/lesões , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/veterinária
16.
J Feline Med Surg ; 17(6): 468-75, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25139540

RESUMO

Limited information is available on pre-analytical variations in plasma analytes in cats. The objectives of this study were to assess the effects of the time of sampling and a standard meal on plasma analytes in healthy cats. Eight healthy, adult, fasted cats underwent blood sampling every 2 h from 8 am to 8 pm twice at a 12 day interval. On the days of sampling, four cats were kept fasted and the others were fed just after the first sample, in a crossover design. Plasma glucose, urea, creatinine, sodium, potassium, chloride, CO2, calcium, phosphate, proteins, albumin, cholesterol and triglycerides, alanine aminotransferase and alkaline phosphatase were assayed on each sample. Effects of time of sampling and meal on plasma biochemistry results were tested using a general linear model. Diurnal variations in tested plasma analytes in fasted cats were negligible except for urea and creatinine, which gave noticeably higher plasma concentrations in the afternoon than in the morning. Observed postprandial variations were of some importance for phosphate and creatinine and of indisputable clinical relevance for CO2 and urea.


Assuntos
Análise Química do Sangue/veterinária , Gatos/sangue , Dieta/veterinária , Jejum , Período Pós-Prandial , Fenômenos Fisiológicos da Nutrição Animal , Animais , Ingestão de Energia , Valores de Referência
17.
J Feline Med Surg ; 17(2): 94-100, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24782457

RESUMO

The objective of this study was to determine the influence of the observer's level of experience on within- and between-day variability, and the percentage of successful systolic (SAP) and diastolic arterial blood pressure (DAP) measurements obtained by Doppler ultrasonography (DU) in awake cats. For this purpose, six healthy conscious cats were used and four observers with different levels of training performed 144 SAP and DAP measurements on 4 days using DU. Measurements were recorded five consecutive times, and mean values were used for statistical analysis. Only the two most skilled observers - a PhD student in cardiology and a Dipl ECVIM-CA (cardiology) - had within- and between-day coefficients of variation (CVs) for SAP ⩽16% (13-16%). Conversely, the two less experienced observers - a fifth-year student and an assistant - had high between-day CVs (61% and 73%). For DAP, only the most experienced observer (Dipl ECVIM-CA) succeeded in 100% of the attempts, with within- and between-day CVs of 11% and 4%, respectively. Conversely, DAP could not be measured by the other three observers in 8%, 19% and 56% of attempts (from the highest to the lowest level of experience); therefore, the corresponding CV values could not be calculated. In conclusion, SAP may be assessed using DU in healthy awake cats with good repeatability and reproducibility by a well-trained observer. Measurement of DAP is more difficult than of SAP, and needs a longer training period, which represents one of the limitations of DU in cats.


Assuntos
Determinação da Pressão Arterial/veterinária , Gatos/fisiologia , Ultrassonografia Doppler/veterinária , Animais , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Estado de Consciência , Oscilometria/veterinária , Valores de Referência , Reprodutibilidade dos Testes , Ultrassonografia Doppler/métodos
18.
J Feline Med Surg ; 17(10): 880-8, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25425599

RESUMO

OBJECTIVES: Diabetic kidney disease (DKD) is a frequent and serious complication in human diabetic patients, but data are limited in cats. This study was undertaken to assess whether diabetic cats are susceptible to DKD. METHODS: Kidney function was compared between 36 cats with diabetes mellitus (DM), 10 cats with chronic kidney disease (CKD) and 10 age-matched healthy cats by measuring routine kidney variables (serum creatinine [sCreat], serum urea [sUrea], urine specific gravity [USG], urinary protein:creatinine ratio [UPC]), urinary cystatin C:creatinine ratio and glomerular filtration rate (GFR). Urinary cystatin C (uCysC) was measured with a human particle-enhanced nephelometric immunoassay, validated to measure feline cystatin C, in all but two diabetic cats. GFR was evaluated by exo-iohexol clearance in 17 diabetic cats, all cats with CKD and all healthy cats. RESULTS: Diabetic cats had significantly (mean ± SD) lower sCreat (123 ± 38 vs 243 ± 80 µmol/l), sUrea (11 ± 3 vs 18 ± 7 mmol/l) and urinary cystatin C:creatinine ratio (6 ± 31 vs 173 ± 242 mg/mol), and a significantly higher USG (1.033 ± 0.012 vs 1.018 ± 0.006) and GFR (2.0 ± 0.7 vs 0.8 ± 0.3 ml/min/kg) compared with cats with CKD. Compared with healthy cats, diabetic cats only had significantly lower USG (1.033 ± 0.012 vs 1.046 ± 0.008). Proteinuria (UPC >0.4) was present in 39% of diabetic cats, in 30% of cats with CKD and in none of the healthy cats. However, the UPC did not differ statistically between the three groups. CONCLUSIONS AND RELEVANCE: Based on evaluation of routine kidney variables, GFR and uCysC as a tubular marker at a single time point, a major impact of feline DM on kidney function could not be demonstrated.


Assuntos
Doenças do Gato/sangue , Doenças do Gato/urina , Cistatina C/urina , Diabetes Mellitus/veterinária , Insuficiência Renal Crônica/veterinária , Animais , Biomarcadores/sangue , Biomarcadores/urina , Nitrogênio da Ureia Sanguínea , Gatos , Creatinina/sangue , Taxa de Filtração Glomerular , Testes de Função Renal/veterinária , Valores de Referência
19.
J Feline Med Surg ; 17(10): 889-900, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25518848

RESUMO

OBJECTIVES: Diagnosis of early feline chronic kidney disease (CKD) is challenging. Glomerular filtration rate (GFR) is the best overall indicator of kidney function, but multisample plasma clearance methods to determine GFR are labour intensive, time consuming and stressful for feline patients. This study aimed to develop simplified methods to detect decreased GFR in cats. METHODS: Data from a nine-sample combined plasma exogenous creatinine-iohexol clearance test of 73 cats were used. Limited sampling strategies were developed by comparing all sampling time combinations with the complete nine sampling times set and selecting the best sampling time combinations based on maximum relative error. By regression analysis, the ability of routine blood (serum creatinine, serum urea) and urine (urine specific gravity, urinary protein:creatinine ratio) variables to predict GFR or identify cats with low or borderline GFR was examined. Cut-off clearance marker concentrations to predict low or borderline GFR was determined at three time points after marker injection. All procedures were analysed for three clearance markers (exo-iohexol, creatinine, endo-iohexol). RESULTS: For reliable estimation of GFR, at least three blood samples for clinical purposes and five blood samples for research purposes are required. Regression formulae based on routine variables did not reliably predict GFR, but accurately identified cats with low (sensitivity 96.5-98.2%; specificity 60-91.3%) or borderline (sensitivity 91.1-96%; specificity 76.5-81.8%) GFR. Clearance marker concentrations exceeding given marker cut-off concentrations also identified cats with low or borderline GFR with high sensitivities and specificities. CONCLUSIONS AND RELEVANCE: These simplified methods will facilitate the detection of early kidney dysfunction in cats. Early diagnosis allows timely therapeutic intervention, and future studies must reveal whether this improves the long-term outcome of cats with CKD.


Assuntos
Doenças do Gato/diagnóstico , Doenças do Gato/urina , Taxa de Filtração Glomerular/veterinária , Insuficiência Renal Crônica/veterinária , Animais , Biomarcadores/urina , Nitrogênio da Ureia Sanguínea , Gatos , Creatinina/urina , Testes de Função Renal/veterinária , Análise de Regressão , Insuficiência Renal Crônica/diagnóstico , Manejo de Espécimes/veterinária
20.
Vet Clin Pathol ; 43(3): 371-80, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25040140

RESUMO

BACKGROUND: Plasma variables may be affected by breed or body weight (BW). Small-sized dogs are very common, but no specific reference intervals (RI) are used. OBJECTIVES: The primary objective of this prospective study was to assess the potential effect of breed, BW, age, and sex on routine plasma analytes and packed cell volume (PCV) in small-sized dogs. A secondary objective was to establish RI in this small-sized population. METHODS: Blood was sampled under standardized conditions from healthy dogs. PCV and 15 routine plasma variables were measured at the same laboratory. Effects of breed, BW, age, and sex were tested using a general linear model. The procedure recommended by the Clinical and Laboratory Standards Institute was used to establish RI. RESULTS: In this study, 154 healthy dogs from 7 breeds were prospectively included. Although a significant effect of breed, BW, sex, or age was evidenced for most variables (except plasma sodium, phosphates, and triglycerides), it was considered as clinically irrelevant. More strikingly, the percentage of values in the reference sample group under the lower limit of the laboratory's RI ranged from 3.8% to 76.6% for 9 variables, and those higher than the upper limit of the laboratory's RI ranged from 4.5% to 9.7% for 7 variables. For example, the RI for creatinine in small-sized dogs was 45-90 µmol/L (vs 54-144 µmol/L for the general dog population). CONCLUSION: Specific RI should be considered for PCV and selected plasma variables in small-sized dogs.


Assuntos
Creatinina/sangue , Cães/sangue , Albumina Sérica/análise , Fatores Etários , Animais , Análise Química do Sangue/veterinária , Tamanho Corporal , Peso Corporal , Cruzamento , Feminino , Hematócrito/normas , Hematócrito/veterinária , Masculino , Estudos Prospectivos , Valores de Referência , Fatores Sexuais , Especificidade da Espécie
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...